1-866-494-4610

Beckett 7505W1500U Primary Beckett 120V

Beckett 7505W1500U Primary Beckett 120V
Images for general purposes only. Actual may be different than depicted.
Beckett 7505W1500U Primary Beckett 120V

Beckett 7505W1500U Primary Beckett 120V

SKU: 7505W1500U
Rating:
Quantity Price Stock
Usually Ships 1-2 Weeks
Usually Ships 1-2 Weeks
$124.50     /ea
Usually Ships 1-2 Weeks
0
$0.00
0
$0.00
0
7505W1500U
Beckett 7505W1500U Primary Beckett 120V

The Beckett GeniSys™ Advanced Burner Control is a 120 VAC primary safety control for residential and light commercial oil burners used in boiler, furnace, and water heater applications. The GeniSys™ is used with a suitable cad cell flame sensor to control the oil burner motor, igniter, and optional solenoid valve. It has 24 VAC thermostat terminals (if applicable) compatible with both mechanical and many power stealing thermostats. It can provide interrupted or intermittent duty ignition, and it has a 15 second lockout time.

Features & Benefits

  • Water Resistant
  • Thermostat and boiler control compatible
  • Water Resistant
  • Customizable pre-time and post-time
  • Three status lights for system monitoring and diagnostics
  • Welded relay protection with redundant motor relays
  • Limited reset and limited recycle
  • Sleek, modern design
  • Technician Pump Prime mode
  • 5-Year Warranty
  • Two communication ports for adding alarm contacts, programming display, and/or future wireless communications

Technical Information

  • Voltage: 102 to 132 VAC
  • Current: 100 mA plus burner motor, igniter, and valve loads
  • Frequency: 60 Hz
  • Motor: 120 VAC, 10 full load amps (FLA), 60 locked rotor amps (LRA)
  • Igniter: 120 VAC, 3 A @ 0.7 PF min
  • Solenoid Valve: 120 VAC, 1 A @ 0.7 PF min
  • Thermostat Anticipator Current: 0.1 A
  • Thermostat Voltage: 24 VAC
  • Storage and Operating Ambient Temperature: -4°F to +150°F (-20°C to +65°C)
  • Moisture: 5-85% RH, non-condensing and non-crystallizing
  • Approvals: Underwriters Laboratory Recognition per UL372 and UL1998, and CSA-B140.0
Voltage 102 to 132 VAC
Current 100 mA plus burner motor, igniter, and valve loads
Frequency 60 Hz
Storage and Operating Ambient Temperature -4°F to +150°F (-20°C to +65°C)
Approvals Underwriters Laboratory Recognition per UL372 and UL1998, and CSA-B140.0

Q & A: Ask the Questions, share answers